How can you tell if your attic is vented at all?

Short answer. Look for intake vents under the eaves and exhaust vents on the roof or gable walls; if you find both and the attic floor is insulated, the attic is vented. If foam insulation is sprayed on the underside of the roof deck and the vents are sealed, it is an intentionally unvented attic; if there is no foam and you find no vents at all, the attic is unvented by accident, which is a problem.

Signs of a vented attic

Signs of an intentionally unvented attic

These are built under the code's unvented attic rules and are fine when done right.

Signs of an accidentally unvented attic

Accidentally unvented attics trap heat and moisture against the deck. Look for dark staining, rusty nails and damp insulation.

Why it matters before a reroof

The roof design depends on which type you have: a vented attic needs balanced intake and exhaust, while an unvented attic needs the vents left closed. See roof ventilation basics and attic heat and shingles.

In depth

How much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with workeDoes a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radiaRidge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust types