Do you need attic ventilation with spray foam, and does a spray foam attic need ventilation?

Short answer. No. When spray foam is applied directly to the underside of the roof deck, the attic becomes an unvented, semi conditioned space, and the soffit and ridge vents are closed rather than left open. If spray foam is used only on the attic floor, the attic above it is still a vented attic and needs normal ventilation.

Two different designs

Code requirements for unvented attics

IRC Section R806.5 sets the conditions, including insulation in direct contact with the underside of the roof deck and an assembly that controls condensation, typically air impermeable insulation such as spray foam at the minimum R-value required for the climate zone. Your building department will look for this on a permit.

Things to know before foaming

The mistake to avoid

Foaming the deck and leaving the ridge and soffit vents open undermines both systems. If you foam, the ventilation gets closed properly. See roof ventilation basics and OSB vs plywood roof decking.

In depth

How much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with workeRidge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust typesDoes a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radia